中文
产品中心
Isolation (rectifying) transformer of charging station
  • Isolation (rectifying) transformer of charging station
  • Isolation (rectifying) transformer of charging station
Isolation (rectifying) transformer of charging station
1.The product is designed with full consideration in good overload capability, low temperature rise and low noise, etc.
2.The product is classified into 6-pulse rectification and 12-pulse rectification. It acts as rectifier transformer during charging and discharging of electric vehicles, thus isolating and protecting vehicle batteries.

Product description:

1.The product is designed with full consideration in good overload capability, low temperature rise and low noise, etc.

2.The product is classified into 6-pulse rectification and 12-pulse rectification. It acts as rectifier transformer during charging and discharging of electric vehicles, thus isolating and protecting vehicle batteries.



Technical parameters:

Technical Parameters of Isolation Transformer for Electric Vehicle

Item

Standard Value

Condition

1

Capacity

0.5KVA-500KVA

2

Voltage range

<1000V

3

Insulation resistance

>100MΩ

DC1000V

4

Dielectric strength

<20mA

AC3.0KV 60s

5

Efficiency

≥98%

Full load

6

Noise

≤65dB

1m away from transformer

7

Temperature rise

≤125K

Full load, self cooling

8

Insulation class

Class H (180℃)

9

Connection mode

Dyn11

10

Short-circuit impedance

6%

11

Ambient temperature

-40℃ - 50℃

12

Design standard

GBT10228

 

Technical Parameters of Reactor for Electric Vehicle

Item

Standard Value

Condition

1

Inductance value

0.1mH-200mH

2

Current range

<500A

3

Insulation resistance

>100MΩ

DC1000V

4

Dielectric strength

<10mA

AC3KV 60s

5

Noise

≤65dB

1m away from transformer

6

Temperature rise

≤125K

Full load, self cooling

7

Insulation class

Class H (180℃)

8

Ambient temperature

-40℃ - 50℃

9

Design standard

GBT10229